dc.contributor.author | Görçay, Hakan | |
dc.contributor.author | Çelik, İlhami | |
dc.contributor.author | Yurdakul, Erman | |
dc.contributor.author | Şahin, Yücel | |
dc.contributor.author | Kökten, Şule | |
dc.date.accessioned | 2019-10-18T18:43:24Z | |
dc.date.available | 2019-10-18T18:43:24Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 1530-437X | |
dc.identifier.issn | 1558-1748 | |
dc.identifier.uri | https://dx.doi.org/10.1109/JSEN.2016.2526609 | |
dc.identifier.uri | https://hdl.handle.net/11421/10248 | |
dc.description | WOS: 000372609000012 | en_US |
dc.description.abstract | A novel and highly sensitive sensor based on poly[2, 5-di(2-thiophenyl)-1-p-(tolyl) pyrrole] was developed and successfully applied for the electrochemical determination of acetaminophen (AC) in pharmaceutical samples. The voltammetric behaviors of AC on modified pencil graphite electrode were investigated by cyclic voltammetry and differential pulse voltammetry in phosphate buffer solution. The voltammetric studies reveal that the polymer modified pencil graphite electrode possesses a remarkable electrocatalytic activity toward acetaminophen compared with the unmodified pencil graphite electrode. A linear dynamic range from 0.025 to 5 mu M and a correlation coefficient of 0.997 with a slope (sensitivity) of 23 mA M-1 were obtained for AC. The detection limit (S/N = 3) was determined as 1.94 nM, which shows a high sensitivity of the developed sensor for AC. | en_US |
dc.description.sponsorship | Anadolu University Research Projects Commission [1401F016] | en_US |
dc.description.sponsorship | This work was supported by the Anadolu University Research Projects Commission under Grant 1401F016. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | IEEE-Inst Electrical Electronics Engineers Inc | en_US |
dc.relation.isversionof | 10.1109/JSEN.2016.2526609 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Acetaminophen | en_US |
dc.subject | Electropolymerization | en_US |
dc.subject | Pencil Graphite Electrode | en_US |
dc.subject | Substituted Pyrrole | en_US |
dc.subject | Voltammetry | en_US |
dc.title | Highly Sensitive Electrochemical Determination of Acetaminophen in Pharmaceuticals by Poly[2, 5-di(2-Thiophenyl)-1-p-(Tolyl) Pyrrole] Modified Pencil Graphite Electrode | en_US |
dc.type | article | en_US |
dc.relation.journal | IEEE Sensors Journal | en_US |
dc.contributor.department | Anadolu Üniversitesi | en_US |
dc.contributor.authorID | Celik, Ilhami/0000-0002-5384-4755; Sahin, Yucel/0000-0001-8590-4073 | en_US |
dc.identifier.volume | 16 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.startpage | 2914 | en_US |
dc.identifier.endpage | 2921 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Çelik, İlhami | |
dc.contributor.institutionauthor | Şahin, Yücel | |