Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzden, Özlem
dc.contributor.authorDöğeroğlu, Tuncay
dc.date.accessioned2019-10-21T20:11:11Z
dc.date.available2019-10-21T20:11:11Z
dc.date.issued2008
dc.identifier.issn0167-6369
dc.identifier.urihttps://dx.doi.org/10.1007/s10661-007-9921-x
dc.identifier.urihttps://hdl.handle.net/11421/20117
dc.descriptionWOS: 000256471500021en_US
dc.descriptionPubMed ID: 17891527en_US
dc.description.abstractThis study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/- 7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 mu g/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R(2)> 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (similar to 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s10661-007-9921-xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAir Pollutionen_US
dc.subjectField Evaluationen_US
dc.subjectMonitoringen_US
dc.subjectNitrogen Dioxideen_US
dc.subjectPassive Sampleren_US
dc.titleField evaluation of a tailor-made new passive sampler for the determination of NO(2) levels in ambient airen_US
dc.typearticleen_US
dc.relation.journalEnvironmental Monitoring and Assessmenten_US
dc.contributor.departmentAnadolu Üniversitesi, Mühendislik Fakültesi, Çevre Mühendisliği Bölümüen_US
dc.identifier.volume142en_US
dc.identifier.issue1.Maren_US
dc.identifier.startpage243en_US
dc.identifier.endpage253en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US