dc.contributor.author | Özden, Özlem | |
dc.contributor.author | Döğeroğlu, Tuncay | |
dc.date.accessioned | 2019-10-21T20:11:11Z | |
dc.date.available | 2019-10-21T20:11:11Z | |
dc.date.issued | 2008 | |
dc.identifier.issn | 0167-6369 | |
dc.identifier.uri | https://dx.doi.org/10.1007/s10661-007-9921-x | |
dc.identifier.uri | https://hdl.handle.net/11421/20117 | |
dc.description | WOS: 000256471500021 | en_US |
dc.description | PubMed ID: 17891527 | en_US |
dc.description.abstract | This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/- 7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 mu g/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R(2)> 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (similar to 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Springer | en_US |
dc.relation.isversionof | 10.1007/s10661-007-9921-x | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Air Pollution | en_US |
dc.subject | Field Evaluation | en_US |
dc.subject | Monitoring | en_US |
dc.subject | Nitrogen Dioxide | en_US |
dc.subject | Passive Sampler | en_US |
dc.title | Field evaluation of a tailor-made new passive sampler for the determination of NO(2) levels in ambient air | en_US |
dc.type | article | en_US |
dc.relation.journal | Environmental Monitoring and Assessment | en_US |
dc.contributor.department | Anadolu Üniversitesi, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | en_US |
dc.identifier.volume | 142 | en_US |
dc.identifier.issue | 1.Mar | en_US |
dc.identifier.startpage | 243 | en_US |
dc.identifier.endpage | 253 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Döğeroğlu, Tuncay | |