dc.contributor.author | Yenisoy-Karakaş, Serpil | |
dc.contributor.author | Gaga, Eftade Emine | |
dc.contributor.author | Cankur, Oktay | |
dc.contributor.author | Karakaş, Duran | |
dc.date.accessioned | 2019-10-21T20:11:05Z | |
dc.date.available | 2019-10-21T20:11:05Z | |
dc.date.issued | 2009 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.uri | https://dx.doi.org/10.1016/j.talanta.2009.05.044 | |
dc.identifier.uri | https://hdl.handle.net/11421/20078 | |
dc.description | WOS: 000269288400019 | en_US |
dc.description | PubMed ID: 19635363 | en_US |
dc.description.abstract | Simultaneous and multi-elemental method was optimized to determine 35 elements in 274 coarse and fine aerosol samples by using HR-ICP-MS. The procedures were validated. Measurement uncertainties of all elements including sampling uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each element ranged between 79% and 129% using NIST SRM 1648, urban dust. The calculated uncertainties of the analytical methods were between 2.9% and 18% for both sample types. The major contributions to the uncertainty budget come from the calibration curves, repeatability and volume of air | en_US |
dc.description.sponsorship | Scientific and Technological Research Council of Turkey [104Y263]; University Research Fund [BAP050222] | en_US |
dc.description.sponsorship | This work was financed by the Scientific and Technological Research Council of Turkey (project number: TUBITAK 104Y263) and Anadolu University Research Fund (project number: BAP050222). The authors would like to thank Akif An and Ozlem Erkan for their assistance in sampling and sample preparation. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Science BV | en_US |
dc.relation.isversionof | 10.1016/j.talanta.2009.05.044 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Elements | en_US |
dc.subject | Aerosols | en_US |
dc.subject | High Resolution Inductively Coupled Plasma Mass Spectrometry | en_US |
dc.subject | Method Validation | en_US |
dc.subject | Microwave Digestion | en_US |
dc.subject | Uncertainty | en_US |
dc.title | Uncertainty of high resolution inductively coupled plasma mass spectrometry based aerosol measurements | en_US |
dc.type | article | en_US |
dc.relation.journal | Talanta | en_US |
dc.contributor.department | Anadolu Üniversitesi, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | en_US |
dc.identifier.volume | 79 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 1298 | en_US |
dc.identifier.endpage | 1305 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Gaga, Eftade Emine | |