dc.description.abstractHVAC systems use the largest share of energy consumption in airport terminal buildings. Thus, the efficiency of the HVAC system and the performance of the building envelope have great importance in reducing the energy used for heating and cooling purposes. In this study, the application of thermal insulation on the walls and roof of the Hasan Polatkan Airport terminal building was investigated from energy, environment and cost aspects. This study determined the optimum insulation thickness and assessed its effects on environmental performance based on energy flows. Environmental payback periods were calculated depending on the optimum insulation thickness. The life cycle assessment (LCA) method was used to assess whether the decrease in energy consumption after applying the insulation balanced the environmental effects during the period between the production and application of the thermal insulation material. The global warming potential (GWP) based on IPCC100, and the effects on human health (HH), the ecosystem and natural resources were evaluated according to the ReCiPe method. LCA results were obtained by processing data taken from ecoinvent 3 database present in the Sima Pro 8.3.0.0 software. Applying thermal insulation on the walls and roof of the terminal building was found to decrease heat loss by 48% and 56%, respectively. In addition, the analyses showed that the environmental payback periods for the thermal insulation were shorter than the economic payback periods.en_US
dc.description.sponsorshipAnadolu University Scientific Research Projects Commission [1610F668]en_US
dc.description.sponsorshipThis study was supported by the Anadolu University Scientific Research Projects Commission under Grant No. 1610F668.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.relation.isversionof10.3390/su9101849en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLife Cycle Assessmenten_US
dc.subjectOptimum Insulation Thicknessen_US
dc.subjectBuilding Insulationen_US
dc.subjectIpcc Gwpen_US
dc.subjectRecipeen_US
dc.subjectAirportsen_US
dc.titleEconomic and Environmental Optimization of an Airport Terminal Building's Wall and Roof Insulationen_US
dc.typearticleen_US
dc.relation.journalSustainabilityen_US
dc.contributor.departmentAnadolu Üniversitesi, Havacılık ve Uzay Bilimleri Fakültesi, Uçak Gövde Motor Bakım Bölümüen_US
dc.identifier.volume9en_US
dc.identifier.issue10en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.contributor.institutionauthorAltuntaş, Önder