Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCandan, Nilgün
dc.contributor.authorTuzmen, Nalan
dc.contributor.authorAndaç, Muge
dc.contributor.authorAndaç, Cenk A.
dc.contributor.authorSay, Rıdvan
dc.contributor.authorDenizli, Adil
dc.date.accessioned2019-10-20T09:13:55Z
dc.date.available2019-10-20T09:13:55Z
dc.date.issued2009
dc.identifier.issn0928-4931
dc.identifier.urihttps://dx.doi.org/10.1016/j.msec.2008.06.002
dc.identifier.urihttps://hdl.handle.net/11421/17098
dc.descriptionWOS: 000262136700023en_US
dc.description.abstractThe aim of this study is to utilize ion-imprinted magnetic beads in the selective removal of Cd2+ ions out of human plasma overdosed with Cd2+ ions. The Cd (2+) imprinted magnetic poly(HEMA-MAC) (mPHEMAC-Cd2+) beads were produced by suspension polymerization in the presence of magnetite Fe3O4 in a nano-powder form. The template Cd2+ ions could be reversibly detached from the matrix to form mPHEMAC-Cd2+ beads using 0.1 M thiourea solution. The specific surface area of the mPHEMAC-Cd2+ beads was found to be 24.7 m(2)/g. The MAC and Fe3O4 contents of the mPHEMAC-Cd2+ beads were found to be 41.8 mu mol/g polymer and 8.2% on the average. The Cd2+ adsorption capacity of mPHEMAC-Cd2+ columns decreased drastically from 48.8 mu mol/g to 20.0 mu mol/g as the flow rate is increased from 0.50 ml/min to 3.0 ml/min. The maximum adsorption capacity of the mPHEMAC-Cd2+ beads was determined to be 48.8 mu mol Cd2+/g on the average. The relative selectivity coefficients of the mPHEMAC beads for Cd2+/Pb2+ and Cd2+/Zn2+ were 22.6 and 160.7 times greater than those of the non-imprinted magnetic PHEMAC (mPHEMAC) beads, respectively. The mPHEMAC-Cd2+ beads are reusable for many times with no significant decrease in their adsorption capacitiesen_US
dc.language.isoengen_US
dc.publisherElsevier Science BVen_US
dc.relation.isversionof10.1016/j.msec.2008.06.002en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIon Imprintingen_US
dc.subjectMagnetic Beadsen_US
dc.subjectMolecular Recognitionen_US
dc.subjectCadmium Removalen_US
dc.subjectMetal Detoxificationen_US
dc.subjectAffinity Bindingen_US
dc.titleCadmium removal out of human plasma using ion-imprinted beads in a magnetic columnen_US
dc.typearticleen_US
dc.relation.journalMaterials Science & Engineering C-Biomimetic and Supramolecular Systemsen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume29en_US
dc.identifier.issue1en_US
dc.identifier.startpage144en_US
dc.identifier.endpage152en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorSay, Rıdvan


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster