Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAslıyüce, Sevgi
dc.contributor.authorUzun, Lokman
dc.contributor.authorRad, Abbas Yousefi
dc.contributor.authorÜnal, Serhat
dc.contributor.authorSay, Rıdvan
dc.contributor.authorDenizli, Adil
dc.date.accessioned2019-10-20T09:13:54Z
dc.date.available2019-10-20T09:13:54Z
dc.date.issued2012
dc.identifier.issn1570-0232
dc.identifier.urihttps://dx.doi.org/10.1016/j.jchromb.2012.02.001
dc.identifier.urihttps://hdl.handle.net/11421/17095
dc.descriptionWOS: 000302452600014en_US
dc.descriptionPubMed ID: 22382092en_US
dc.description.abstractIn the present study, we have focused our attention to prepare molecular imprinted composite cryogel membranes for purification of hepatitis B surface antibody (anti-HBs) by fast protein liquid chromatography. Before the preparation of the molecular imprinted composite cryogel membranes (MI-CMs) by free radical polymerization at sub-zero temperature, we have synthesized and characterized the anti-HBs imprinted particles. Then, the cryogel membranes (CMs) were characterized by swelling test, scanning electron microscopy and Fourier transform infrared spectroscopy. Prior to chromatographic purification studies, the effective parameters on the anti-HBs adsorption process were evaluated by investigating the dependency of the adsorption capacity on flow-rate, anti-HBs concentration, contact time and ionic strength. The maximum anti-HBs adsorption capacity was calculated as 701.4 mIU/g CM. The selectivity of the MI-CMs was shown by competitive adsorption of anti-HBs, total anti-hepatitis A antibody (anti-HAV) and total immunoglobulin E (IgE) adsorption studies. The MI-CMs have relative selectivity coefficients as 5.45 for anti-HBs/total anti-HAV and 9.05 for anti-HBs/total IgE, respectively. The phosphate buffer solution (pH 7.4) containing 1.0 M NaCl was used for elution, almost completely, of adsorbed anti-HBs molecules. The MI-CMs could be used many times without any significant decrease in the adsorption capacity. The chromatographic purification performances of the MI-CMs were also investigated. The chromatographic parameters such as capacity and separation factors, the theoretical plate number and resolution of the MI-CMs were calculated as 5.48, 6.02, 1153.9, and 1.72 for anti-HBs molecules, respectively. As a conclusion, we can say that the MI-CMs could be used for specific purification of anti-HBs from anti-HBs positive human plasmaen_US
dc.language.isoengen_US
dc.publisherElsevier Science BVen_US
dc.relation.isversionof10.1016/j.jchromb.2012.02.001en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMolecular Imprinted Polymersen_US
dc.subjectAnti-Hepatitis B Surface Antibodyen_US
dc.subjectComposite Cryogel Membraneen_US
dc.subjectFast Protein Liquid Chromatographyen_US
dc.subjectAffinity Purificationen_US
dc.titleMolecular imprinting based composite cryogel membranes for purification of anti-hepatitis B surface antibody by fast protein liquid chromatographyen_US
dc.typearticleen_US
dc.relation.journalJournal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciencesen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume889en_US
dc.identifier.startpage95en_US
dc.identifier.endpage102en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorSay, Rıdvan


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster