dc.description.abstractIn this work, it was used a polypyrrole (PPy) electrode as a potentiometric electrochemical detector in a flow injection system in order to determine sulfamethoxazole in pharmaceutical formulations. The PPy electrode was prepared by cyclic voltammetry in acetonitrile solution. A linear relationship was observed over the concentration range of 2.5 x 10(-5)-1.25 x 10(-3) mol L(-1) with a correlation coefficient of 0.9977 and limit of detection (LOD) of 1.03 x 10(-6) mol L(-1) (SIN = 3). The recoveries in tablet and syrup formulations were found as 97.4 and 90.8% with the relative standard deviations of 0.62 and 1.04%, respectively, which closely agree with those measured by high performance liquid chromatography (HPLC) with UV detector. Therefore, it was concluded that the PPy electrode can be used as an alternative novel potentiometric detector material for determination of sulfamethoxazole in pharmaceuticals with the advantages of easy preparation and regeneration capability of the electrode surface.en_US
dc.description.sponsorshipSuleyman Demirel University [1202-D-05]; Anadolu University [031064]en_US
dc.description.sponsorshipFinancial supports of Suleyman Demirel University (Projects No. 1202-D-05) and Anadolu University (Project No. 031064) are gratefully acknowledged.en_US
dc.language.isoengen_US
dc.publisherSoc Brasileira Quimicaen_US
dc.relation.isversionof10.1590/S0103-50532011001100021en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSulfamethoxazoleen_US
dc.subjectPotentiometric Detectionen_US
dc.subjectFlow Injection Systemen_US
dc.subjectHplcen_US
dc.subjectPharmaceuticalsen_US
dc.titleDetermination of Sulfamethoxazole in Pharmaceutical Formulations by Flow Injection System/HPLC with Potentiometric Detection using Polypyrrole Electrodeen_US
dc.typearticleen_US
dc.relation.journalJournal of the Brazilian Chemical Societyen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume22en_US
dc.identifier.issue11en_US
dc.identifier.startpage2171en_US
dc.identifier.endpage2177en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorŞahin, Yücel


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster