dc.description.abstract | In this study, an electrochemical sensor was developed for the determination of propham (PRO) in potato, human urine and river water samples based on the over-oxidized poly(thiophene) modified pencil graphite [PG/p(Thp)-Ox] electrode. Adsorptive stripping differential pulse voltammetry was used as a voltammetric method. The PG/p(Thp)-Ox electrode increased the oxidation peak current of PRO 30 times according to bare PG. Electrochemical polymerization and over-oxidation conditions were deeply optimized to increase the sensitivity of PG/p(Thp)-Ox. Characterization of PG/p(Thp)-Ox was performed via scanning electron microscopy and cyclic voltammetry analysis. Oxidation peak current value of PRO linearly increased with the concentration of PRO in the ranges of 0.005-1.0 mu M and 2.0-15.0 mu M. A very low limit of detection value (1.0 nM) was obtained. Intra-day and inter-day reproducibility of the PG/p(Thp)-Ox were determined as 2.96% (N: 10) and 4.77% (10 days), respectively. Satisfactory recovery values (98.07-104.4%) were observed with PG/p(Thp)-Ox electrode during the analysis of PRO in PRO-spiked potato, urine and river water samples. The results show that the PG/p(Thp)-Ox could be used safely in the determination of PRO. | en_US |
dc.description.sponsorship | Anadolu University Scientific Research Projects Commission [1605F334, 1701F011] | en_US |
dc.description.sponsorship | This study was supported by Anadolu University Scientific Research Projects Commission under the grant numbers of 1605F334 and 1701F011. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Science BV | en_US |
dc.relation.isversionof | 10.1016/j.talanta.2018.05.018 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Poly(Thiophene) | en_US |
dc.subject | Propham | en_US |
dc.subject | Pencil Graphite | en_US |
dc.subject | Electrochemical Sensor | en_US |
dc.subject | Electrochemical Over-Oxidation | en_US |
dc.title | Preparation of a disposable and low-cost electrochemical sensor for propham detection based on over-oxidized poly(thiophene) modified pencil graphite electrode | en_US |
dc.type | article | en_US |
dc.relation.journal | Talanta | en_US |
dc.contributor.department | Anadolu Üniversitesi, Fen Fakültesi, Fizik Bölümü | en_US |
dc.identifier.volume | 187 | en_US |
dc.identifier.startpage | 125 | en_US |
dc.identifier.endpage | 132 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Özcan, Ali | |