Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorGürbüz, Mustafa
dc.contributor.authorÖzcan, Ayça Atılır
dc.contributor.authorÖzcan, Ali
dc.date.accessioned2019-10-20T09:13:21Z
dc.date.available2019-10-20T09:13:21Z
dc.date.issued2018
dc.identifier.issn1573-4129
dc.identifier.issn1875-676X
dc.identifier.urihttps://dx.doi.org/10.2174/1573412913666170317130625
dc.identifier.urihttps://hdl.handle.net/11421/16848
dc.descriptionWOS: 000430100800012en_US
dc.description.abstractBackground: Levofloxacin (LVX) is one of the fluoroquinolone antibiotics that possess a wide spectrum of bactericidal activity against both Gram-positive and Gram-negative bacteria. Because of its side effects and its potential towards the development of antibiotic resistance, determination of this antibiotic is very important. New methods which have superior properties than the conventional methods are needed in the determination of pharmaceuticals in different samples. Method: An activated pencil graphite electrode (A-PGE) was prepared and its application in the voltammetric determination of LVX in pharmaceutical samples and body fluids was searched. Results: Oxidation peak currents of LVX were increased 40 times in the presence of A-PGE according to bare PGE. The highest voltammetric response of A-PGE towards LVX was achieved at pH value of 4. A wide linear range (0.01-2.5 mu M) was observed between the oxidation peak currents and concentrations of LVX. Detection limit was calculated as 0.0075 mu M. The inter-day (five days) precision of APGE was found to be 3.16%. Interference studies showed that A-PGE successfully discriminated the voltammetric response of LVX from that of many other structurally related substances such as ciprofloxacin, norfloxacin and enoxacin. Prepared A-PGE preserved 87% of its original activity towards LVX after a 2-month storage. Determination of LVX in blood serum, urine and pharmaceuticals was successfully achieved by A-PGE. Conclusion: The prepared A-PGE brings two important advantages. First one is the selective response of A-PGE towards LVX in the presence of other fluoroquinolone antibiotics (ciprofloxacin, enoxacin and norfloxacin). The other is the high sensitivity of A-PGE towards LVX having the detection limit of 0.0075 mu M. In addition to the given advantages, its disposable character, low cost, commercial availability and easy preparation of A-PGE make this electrode an important candidate in the fast and accurate determination of LVX.en_US
dc.description.sponsorshipAnadolu University Scientific Research Projects Commission [1605F334]en_US
dc.description.sponsorshipFinancial support of Anadolu University Scientific Research Projects Commission (Project No: 1605F334) is gratefully acknowledged.en_US
dc.language.isoengen_US
dc.publisherBentham Science Publ LTDen_US
dc.relation.isversionof10.2174/1573412913666170317130625en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectLevofloxacinen_US
dc.subjectPencil Graphiteen_US
dc.subjectVoltammetryen_US
dc.subjectElectrochemical Overoxidationen_US
dc.subjectElectrodeen_US
dc.subjectFluoroquinoloneen_US
dc.titlePreparation of Activated Disposable Pencil Graphite Electrode for the Selective and Sensitive Determination of a Fluoroquinolone Antibiotic: Levofloxacinen_US
dc.typearticleen_US
dc.relation.journalCurrent Pharmaceutical Analysisen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume14en_US
dc.identifier.issue3en_US
dc.identifier.startpage247en_US
dc.identifier.endpage254en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorÖzcan, Ali


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster